Mount AC module to the PV rack in the following order:
•
Place AC modules on the PV rack with a minimum gap of 6mm (0.236 inches) between each module. To prevent the
risk of slipping during installation, mount AC modules one by one.
•
Peel the adhesive label attached on the side of AC module frame and attach the identification label on LG AC module
Installation map. The map makes it easy for customers to identify the physical location of a particular AC module.
Each AC module has two MAC ID labels. One is placed under the product specification label. And the other is the
detachable MAC ID label.
•
The layout of the array will be utilized for building a monitoring system allowing a customer to check the amount of
energy harvested.
•
The AC modules can be mounted in landscape or portrait orientation, as illustrated below.
•
When the AC module is mounted on a PV rack rail, ensure that the rail is inside the range specified in Appendix 2 –
Module Installation & Load Guide. The range varies depending on mounting methods.
•
Appendix 2 guides you how to place PV rack rails and clamps in connection with AC modules.
60 cell
① : 200mm (7.9 in)
② : 300mm (11.8 in)
This mounting method uses frame bolt holes.
Please refer to
Appendix 2 –Module Installation & Load Guide
.
②
②
•
To prevent the risk of accidents, use proper PPE (Personal Protective Equipment) including
helmets and gloves at all times.
•
If installation location is high above ground, make sure to use Fall Protection System during
the installation.
Design Strength (Basic Load)
•
60Cell Modules: 75lb/ft2
•
Detail of mounting distance is below.