Outdoor Units
14
_
Heat pump 60Hz/R410A
1. DC Inverter SINGLE ZONE
SINGLE ZONE
1.11 Field wiring diagrams
1. All wiring must comply with LOCAL REGULATIONS.
2. Select a power source that is capable of supplying the current as required by the air conditioner.
3. Feed the power source to the unit via a distribution switch board designed for this purpose.
4. The terminal screws inside the control box may be loose due to vibration during transport.
Check the screws for loose connection.
(Running the air conditioner with loose connection can overload and damage electrical components.)
5. Always ground the air conditioner with a grounding wire and connector to meet the LOCAL REGULATION.
Notes:
1. All wirings, components and materials to be procured on the site should be according to the standard
2. Use copper conductor only
3. Install circuit breaker for safety
4.
5. Wiring cable size must comply with the applicable local and national code.
Unit should be grounded in compliance with the applicable local and national codes
L
L
N
N
G
Power supply
Main switch
Circuit breaker
Fuse
Power cable (Including earth)
Outdoor unit
1(L1) 2(L2)
Terminal Block outdoor
1(L1) 2(L2)
3
Terminal Block outdoor
Communication
Line
1(L1) 2(L2)
Terminal Block Indoor
3
Содержание ATNH24GPLE2
Страница 1: ...SINGLE ZONE Heat pump 60Hz R410A 6CSL0 01B Replaces 6CSL0 01A ...
Страница 2: ...SINGLE ZONE General Information Indoor Units Outdoor Units Design and installation ...
Страница 5: ...SINGLE ZONE Part 1 General information 1 Model Line up 2 Nomenclature 3 Individual Control System ...
Страница 9: ...SINGLE ZONE Part 2 Product data n Indoor units n Outdoor units ...
Страница 14: ...Indoor Units 4 _ Heat pump 60Hz R410A 1 Ceiling cassette 4 way SINGLE ZONE TM Chassis ATNH42GMLE2 LCN427HV ...
Страница 26: ...Outdoor Units 6 _ Heat pump 60Hz R410A 1 DC Inverter SINGLE ZONE SINGLE ZONE U3 Chassis AUUW42GD2 LUU427HV ...