• Use only copper wires.
• Make sure to shut down the power before starting the electric wiring work.
Do not set ON any switch until the work is completed.
• The outdoor unit has an inverter compresser which generates noise and charges the outer casing with the leakag current.
The outdoor unit should be grounded so that the effect of the generated noise on othe equipment can be reduced, and
that the outer casing can be discharged.
• Never install a phase advancing capacitor for power factor improvement.
(Even if it is installed, the power factor is not improved. And if it is installed, the outdoor unit is abnormally overheated.)
• Use specified electric wires in the wiring, and connect them securely.
Fix them in such a way that external force is not applied at the terminals
(transmission wiring in the local field and ground terminal).
• Never push excessive electric wires into the units.
• Protect electric wires with conduit tubes or other proper tubes so that they will not be damaged by edges of knock holes.
• Do not use multi conductor cable which have more than 5 wires in one core.
2. Guideline for each installation process
24
_
Heat pump 60Hz/R410A
Installation of
Outdoor Units
SINGLE ZONE
Содержание ATNH24GPLE2
Страница 1: ...SINGLE ZONE Heat pump 60Hz R410A 6CSL0 01B Replaces 6CSL0 01A ...
Страница 2: ...SINGLE ZONE General Information Indoor Units Outdoor Units Design and installation ...
Страница 5: ...SINGLE ZONE Part 1 General information 1 Model Line up 2 Nomenclature 3 Individual Control System ...
Страница 9: ...SINGLE ZONE Part 2 Product data n Indoor units n Outdoor units ...
Страница 14: ...Indoor Units 4 _ Heat pump 60Hz R410A 1 Ceiling cassette 4 way SINGLE ZONE TM Chassis ATNH42GMLE2 LCN427HV ...
Страница 26: ...Outdoor Units 6 _ Heat pump 60Hz R410A 1 DC Inverter SINGLE ZONE SINGLE ZONE U3 Chassis AUUW42GD2 LUU427HV ...