MULTI/SINGLE
Indoor unit
8. Installation
28
Ceiling Suspended Unit
Important
8.3.2 Drain test
Drainage test of indoor unit
• Hook on the bracket after connecting the drain hose
as shown figure.
• The drain hose should point downward for easy drain
flow.
• Do not make drain piping like the following.
• Be sure to execute heat insulation on the drain piping.
* The feature can be changed according to type of model.
Use the following procedure to test the drainage.
1.In case that there are air filter, remove the air filter first.
2.Spray one or two glasses of water on the evaporator.
3.Check the drainage. Ensure that water flows through drain
hose of indoor unit without any leakage.
kG
i
Downward slope
Do not raise
Water
leakage
Accumulated
drain water
Air
Waving
Water
leakage
Tip of drain hose
dipped in water
Water
leakage
Ditch
Less than
50mm gap
※
According to type of indoor unit,
external appearance could be different.
Содержание AMNW07GSJL0
Страница 1: ...Indoor unit R32 Heat Pump 50 60Hz 0CTI5 08B Replaces 0CTI5 08A P No MFL67502513 ...
Страница 2: ...MULTI SINGLE Indoor unit General information Product data ...
Страница 3: ...General information MULTI SINGLE Indoor unit 1 Model Line Up 2 External Appearance 3 Nomenclature ...
Страница 34: ...22 MULTI SINGLE Indoor unit Wall Mounted Unit 1 5 Wiring Diagrams Deluxe AMNW07GSJL0 DM07RP NSJ ...
Страница 142: ...7 MULTI SINGLE Indoor unit Wall Mounted Unit 4 5 Wiring Diagrams ZJNW30GRLA1 US30F NR0 ZJNW36GRLA1 US36F NR0 ...
Страница 203: ...5 MULTI SINGLE CAC Indoor unit ART COOL 3 Dimensions ZMNW09GAF10 MA09R NF1 ZMNW12GAF10 MA12R NF1 ...
Страница 205: ...7 MULTI SINGLE CAC Indoor unit ART COOL 5 Wiring Diagrams Models ZMNW09GAF10 MA09R NF1 ZMNW12GAF10 MA12R NF1 ...