8. Installation
15
MULTI/SINGLE CAC
Indoor unit
ART COOL
8.3 Connection of piping
• Preparing the indoor unit's piping and drain hose for installation through the wall.
1.
Route the indoor tubing and the drain hose in the direction of rear left or right
2.
Tape the tubing, drain hose and the connecting cable. Make sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.
Note
• If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from
condensation will not damage furniture or floors.
• Foamed polyethylene or equivalent is recommended.
̰
Connecting the installation pipe and drain hose
1. Align the center of the pipes and sufficiently tighten the flare nut by hand.
2. Tighten the flare nut with a wrench.
3. When needed to extend the drain hose of indoor unit, assembly the drain pipe as shown on the drawing.
Drain hose
Loop
Connecting
pipe
Power cable
Transmission
cable
Tape
Drain hose
Indoor unit tubing
Flare nut Pipes
Wrench
Indoor unit tubing
Open-end wrench
(fixed)
Connection
pipe
Flare nut
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
Содержание AMNW07GSJL0
Страница 1: ...Indoor unit R32 Heat Pump 50 60Hz 0CTI5 08B Replaces 0CTI5 08A P No MFL67502513 ...
Страница 2: ...MULTI SINGLE Indoor unit General information Product data ...
Страница 3: ...General information MULTI SINGLE Indoor unit 1 Model Line Up 2 External Appearance 3 Nomenclature ...
Страница 34: ...22 MULTI SINGLE Indoor unit Wall Mounted Unit 1 5 Wiring Diagrams Deluxe AMNW07GSJL0 DM07RP NSJ ...
Страница 142: ...7 MULTI SINGLE Indoor unit Wall Mounted Unit 4 5 Wiring Diagrams ZJNW30GRLA1 US30F NR0 ZJNW36GRLA1 US36F NR0 ...
Страница 203: ...5 MULTI SINGLE CAC Indoor unit ART COOL 3 Dimensions ZMNW09GAF10 MA09R NF1 ZMNW12GAF10 MA12R NF1 ...
Страница 205: ...7 MULTI SINGLE CAC Indoor unit ART COOL 5 Wiring Diagrams Models ZMNW09GAF10 MA09R NF1 ZMNW12GAF10 MA12R NF1 ...