System Set-Up
Installation Manual
53
ENGLISH
2) Outdoor
SW01B
1
2
3 4
5
6
7
ON
SW02B
<Initial shipping condition of DIP Switch>
1
2
3 4
5
6
7
ON
SW01B
(DIP S/W)
SW02B
(DIP S/W)
7 - Segment
SW02V
Auto addressing
SW01V
Data confirm
1. When outdoor unit is powered on after con-
figuring the DIP switch, proper input of con-
figuration value can be verified through
7-Segment.
2. This function is shown only for 2 seconds
after turning on the power.
n
Verification of outdoor unit configuration
- After power is turned on, number are
shown on 7-Segment consecutively
- These numbers show the configuration
status
Main PCB
Model Code
In case of 1Ø, 16 kW model
WARNING
• Main PCB power should be reset in order to recognize the changed function after handling the DIP
switch for configuration of additional functions.
• Main PCB power should be reset after resetting the DIP switch for cancellation of additional function
• Please configure DIP switch properly. Otherwise, It can overstrain product during operation
CAUTION
1. “X” mark means DIP switch must be off, Otherwise the function may not perates correctly.
2. If each DIP switch doesn’t set correctly, unit will operate abnormally.
3. In case of proceeding test run, start after checking if all indoor unit is off.
Phase
Capacity(kW)
Model code Model type
1Ø
16
31
30
Seqence
NO.
Content
1
31
Model code, 1~255
2
5
Nominal Capacity(HP)
3
2
2 : heatpump
No display : cooling only
4
25
Normal
5
30
Model type, 1~255