Be sure to read carefully the safety precautions given in data sheet and user’s manual before operating the module
and follow them.
The precautions explained here only apply to the G3F-DA4V, G3F-DA4I and G4F-DA1A(hereafter, called D/A con-
version module)
For safety precautions on the PLC system, see the GLOFA GM3/4 User’s Manuals and the MASTER-K200S/300S/
1000S CPU User’s Manuals.
A precaution is given with a hazard alert triangular symbol to call your attention, and precautions are repres ented
as follows according to the degree of hazard.
However, a precaution followed with can also result in serious conditions.
Both of two symbols indicate that an important content is mentioned, therefore, be sure to observe it.
Keep this manual handy for your quick reference in necessary.
SAFETY PRECAUTIONS
WARNING
!
If not provided with proper prevention, it can cause death or fatal
injury or considerable loss of property.
CAUTION
!
If not properly observed, it can cause a hazard situation to result
in severe or slight injury or a loss of property.
CAUTION
!
CAUTION
!
Design Precautions
▶
Design a safety circuit in the outside of the PLC for system safety in
case of disorder of the external power or PLC module body. Other-
wise, it can cause injury due to wrong output or malfunction.
1) The following shows analog output states according to various
settings of functions that control analog output. When setting an
output state, be cautious for safety.
Channel Specification
Channel Setting
State
Used
Unused
PLC CPU in RUN state.
A D/A conversion
value is output.
PLC CPU in STOP state
PLC CPU in Error state
Communication error of
the remote I/O station
(When loaded on the
remote I/O station)
A value of the speci-
fied output state will
be output.
0: Median value of the
output range
1: Previous value
2: Max. value of the
output range
3: Min. value of the
output range
Voltage:
0 V
Current:
12 mA
2) Sometimes, fault of output device or internal circuit can make
output abnormal. Design a supervising circuit in the outside for
output signals which can cause serious accidents.
CAUTION
!
▶
Do not run I/O
signal lines near
to high voltage
line or power line.
Separate them as
100 mm or more
as possible. Oth-
erwise, noise can
cause module
malfunction
.
Содержание G3F-DA4I
Страница 42: ...Chapter 5 GM PROGRAMMING 5 5 6 I O Variables on Program ...
Страница 44: ...Chapter 5 GM PROGRAMMING 5 7 4 Program INI_STAT ...
Страница 45: ...Chapter 5 GM PROGRAMMING 5 8 5 I O Variables on Program ...
Страница 47: ...Chapter 5 GM PROGRAMMING 5 10 4 Program ...
Страница 48: ...Chapter 5 GM PROGRAMMING 5 11 5 I O Variables on Program ...
Страница 74: ...Chapter 10 G3F PA1A G3F PA2A POWER SUPPLY MODULE 10 3 10 4 Dimensions ...
Страница 75: ...Chapter 11 DIMENSIONS 11 1 Chapter 11 DIMENSIONS 11 1 G3F DA4V G3F DA4I Dimensions ...
Страница 76: ...Chapter 11 DIMENSIONS 11 2 11 2 G4F DA1A Dimensions ...