Page 64
Switching Photocell
Step 2:
Twist strands of each lead tightly (making sure that
there are no stray strands) and push firmly into
appropriate plug connector location.
Step 3:
Tighten the screws on the plug connector making
sure that no bare conductor is showing.
Step 4:
Plug the connector back onto the control module
with the screws facing the front and the wires
coming out of the connector towards the top of the
cabinet.
Step 5:
If using a switched photocell, make sure that the
jumper below the connector is in the "ON" position.
IN +V COM
Switch Leg
PhotoCell
Switch Leg
AC Power
Note: Switch Legs must be
completly isolated from
Photocell AC power and
should be connected to
either side of the switching
relay at the photocell.
Note: If your switching photo-
cell re24VDC power,
this power can be sourced from
the cabinet just like a 0-10VDC
photocell. The switch legs
should still be between COM &
IN terminals