CANopen interface
Leuze electronic
AMS 335
i
61
TNT
35/7-2
4
V
9.5.7.3
Object 100C
h
Guard time
This object is used to configure the device monitoring by the NMT master (node guarding)
together with the life time factor. The monitoring period is specified in milliseconds. If 0 is
entered (default of the AMS 335
i
), the process is deactivated.
9.5.7.4
Object 100D
h
Life time factor
This object must be discussed in connection with object 100C
h
. It represents a value that
yields the lifetime when multiplied by the guard time.
If 0 is entered (default of the AMS 335
i
), the process is deactivated.
9.5.7.5
Object 1017
h
Producer heartbeat time
This object defines the cycle time as a multiple of milliseconds with which the AMS 335
i
sends heartbeat messages into the CANopen network. If the producer heartbeat time is not
used, it is set to the value 0 (zero). By default, the time for the AMS 335
i
is set to 0 (zero),
which means that the AMS 335
i
does not send a cyclical heartbeat signal.
9.5.7.6
Object 1018
h
Identity object
This object contains general specifications about the AMS 335
i
.
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
100C
--
Guard time
u16
rw
0
65535
0
Guard time is deac-
tivated via Default 0
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
100D
--
Life time
u 8
rw
0
255
0
Life time is deacti-
vated via Default 0
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
1017
--
Producer
heartbeat
time
u16
rw 0
65536
0
Producer heartbeat
time is deactivated
via Default 0
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
1018
01
Vendor ID
u 32
ro
--
--
121
h
Manufacturer ID
number
02
Product
code
u 32
ro
--
--
02
h
Product designation