CANopen interface
84
AMS 335
i
Leuze electronic
9.5.9
Objects of the AMS 335
i
from the DS406 class 1 encoder profile
CANopen describes the characteristics of participants in so-called profiles.
The AMS 335
i
communicates according to the specifications in profile "DS406" class 1.
For class 1, it is mandatory to describe the following objects.
9.5.9.1
Object 6000
h
Operating parameters
Bit 0 - Bit 2
not used
Bit 3: counting direction
0 = positive - the measurement value increases with increasing distance.
1 = negative - the measurement value decreases with increasing distance.
Counting direction positive:
Counting direction negative:
Bit 4 - Bit 15: reserve
9.5.9.2
Object 6004
h
Position value
Object 6004
h
contains the position value for process data objects (PDOs) 1A00
h
(TPDO1)
and 1A01
h
(TPDO2).
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
6000
--
Operating
parameters
u16
rw
0
8
0
0= positive count-
ing direction, see
below
0m
+100m
0m
-100m
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
6004
--
Maximum
position
value
int 32
ro
-999999
999999
--
see below
Byte
Bit
Remark
7
6
5
4
3
2
1
0
0
LSB
Maximum position value
1
2
3
MSB