I/O submenu
Table 8.3:
Position value submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Measurement
unit
Metric/Inch
Specifies the units of the measured distances
Metric
Count direction
Positive/Negative
Positive: The measurement value begins at 0 and increases with increas-
ing distance.
Negative: The measurement value begins at 0 and decreases with
increasing distance. Negative distance values may need to be compen-
sated with an offset or preset.
Positive
Offset
Output value=measurement value+offset.
The resolution of the offset value is independent of the selected "Reso-
lution position" and is entered in mm or inch/100. The offset value is
effective immediately following entry. If the preset value is activated, this
has priority over the offset. Preset and offset are not offset against each
other.
0mm
Preset
The preset value is accepted by means of teach pulse. The teach pulse
can be applied to a hardware input of the M12 PWR connector. The hard-
ware input must be appropriately configured. See also configuration of
the I/Os.
0mm
Free resolution
value
The measurement value can be resolved in increments of 1/1000 within
the 5 … 50000 value range. If, e.g., a resolution of 0.875mm per digit
is required, the parameter is set to 875.
In the activated interface, the measurement value display must also be
set to "free resolution" ("Resolution position" parameter).
1000
Error delay
ON / OFF
Specifies whether, in the event of an error, the position value immediately
outputs the value of the "Position value in the case of error" parameter
or the last valid position value for the configured error delay time.
ON/100 ms
Position value in
the case of error
Last valid value / zero
Specifies which position value is output after the error delay time elapses.
Zero
Table 8.4:
I/O submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
I/O 1
Port config-
uration
Input/Output
Defines whether I/O 1 functions as an output or input.
Output
Switching
input
Function
No function/preset teach/laser ON/OFF
No function
Activation
Low active/High active
Low active
Switching
output
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) /
Temp. (TMP) / Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected switching out-
put.
Plausibility (PLB),
hardware (ERR)
Activation
Low active/High active
Low active