CANopen interface
Leuze electronic
AMS 335
i
81
TNT
35/7-2
4
V
Bit 13: intensity (ATT)
If the intensity of the received signal falls below the predefined limit value, the warning is set.
0 = ok
1 = warning
Bit 14: temperature (TMP)
If the internal device temperature lies outside the predefined limit values, the warning is set.
0 = OK
1 = warning
Bit 15: laser (LSR)
If the laser power falls below the predefined limit value, the warning is set.
0 = OK
1 = warning
Bit 16: plausibility (PLB)
If implausible measurement values are diagnosed, the error is set.
0 = OK
1 = error
Bit 17 - Bit 31: reserve
0 = reserve
1 = NC
9.5.8.16 Object 2070
h
Behavior of the AMS 335
i
in the case of error
Explanation on sub-index 01
Bit 0: position value in the case of error
0 = last valid value
1 = zero
Index
Sub-
index
Name
Data
type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
2070
01
Position value in
the case of error
and delay for
error ON/OFF
u8
rw
0
13
13
see below
02
Position error
message delay
u16
rw
100
1000
100
Delay of the error
message in ms
03
Position value in
the case of error
and delay for
error ON/OFF
u8
rw
0
13
13
see below
04
Error delay time
- velocity
u16
rw
200
1000
200