CANopen interface
52
AMS 335
i
Leuze electronic
9.2
Address assignment
Notice
!
The participant-specific address for CANopen is also called the Node ID. Throughout this
handbook, the term "address" is used, which is identical to "Node ID".
Each participant connected to CANopen is assigned its own address (Node ID).
Up to 127 participants can be connected to one network. The addresses range from 1 to
127. The address 0 is usually reserved for the CANopen master.
Notice
!
The "Layer Setting Services (LSS)" function is not supported by the AMS 335
i
. For this rea-
son, the address must be set manually via the display/panel of the AMS.
9.2.1
Entering the address via the display
To enter the address via the display, proceed as follows:
Activate parameter enabling.
Select the CANopen submenu.
Select the Node ID menu item.
Enter an address between 1 and 127.
Save the address with Save.
Deactivate parameter enabling.
Notice
!
Basic operation of the display is described in chapter 8. To set the address, parameter en-
abling must be activated.
Attention!
The laser measurement system is deactivated on the CANopen when parameter enabling is
activated, e.g. for address assignment.
If the AMS 335
i
is connected directly in the trunk line and networked with further participants
via Bus Out, these participants remain active even after the parameter enable has been acti-
vated.
The AMS 335