CANopen interface
Leuze electronic
AMS 335
i
77
TNT
35/7-2
4
V
Bit 11: intensity monitoring (ATT)
If the intensity of the received signal falls below the predefined limit value, the output is set.
0 = OFF
1 = ON
Bit 12: temperature monitoring (TMP)
If the internal device temperature lies outside the predefined limit values, the output is set.
0 = OFF
1 = ON
Bit 13: laser prefailure monitoring (LSR)
If the laser power falls below the predefined limit value, the output is set.
0 = OFF
1 = ON
Bit 14: plausibility monitoring (PLB)
If implausible measurement values are diagnosed, the output is set.
0 = OFF
1 = ON
Bit 15: hardware error (ERR)
If a hardware error is diagnosed, the output is set.
0 = OFF
1 = ON
Bit 16 - Bit 23: reserve
0 = reserve
1 = NC
Bit 24 - Bit 26: function of the I/O 1, if this has been defined as an input
Value 000 =
no function
Value 001 =
Preset teach, valid for static (object 2001) and dynamic (object 2002)
preset
Value 010 =
laser OFF. Laser diode is switched off
Bit 27 - Bit 31: reserve
0 = reserve
1 = NC
9.5.8.14 Object 2051
h
Configuration I/O 2
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
2051
--
I/O2
u32
rw
--
--
--
see below