Electrical installation
INTORQ | BA 14.0197 | 06/2014
30
5
Electrical installation
5.1
Electrical connection
5.1.1
Important notes
DANGER
There is a risk of injury by electrical shock!
❚
Electrical connection must only be carried out by skilled personnel!
❚
Only carry out connection work when no voltage is applied (no live parts)! There is a risk of
unintended start-ups or electric shock.
NOTICE
❚
It must be ensured that the supply voltage corresponds to the name plate data.
NOTICE
❚
If an emergency stop is carried out without the required suppressor circuit, the control unit
may be destroyed.
❚
Observe the correct polarity of the suppressor circuit!
NOTICE
❚
To functionally test the individual brake circuits, the power supply must be able to be
switched off individually. For a new over energisation when switching on, it is also neces-
sary to open switches K1/K3.
❚
The protective circuitry contained in the INTORQ switching device BEG-561-
-
(terminals 3 and 4) is not permitted for use in the lift system. The protective circuitry
must be connected parallel to the brake coil here,
31.