Commissioning and operation
INTORQ | BA 14.0197 | 06/2014
38
6.4
During operation
❚
Checks must be carried out regularly. Pay special attention to:
- unusual noises or temperatures
- loose fixing elements
- the condition of the electrical cables
❚
The armature plate must be attracted and the rotor must move without residual torque.
❚
Measure the DC voltage at the brake.
- The measured DC voltage after the overexcitation time (see bridge/half-wave rectifier,
32) must
correspond to the holding voltage (see table 5). A deviation of ±10 % is permissible.
❚
If faults occur once, go through the troubleshooting table in chapter 8. If the fault cannot be fixed or elim-
inated, please contact your customer service.
DANGER
Danger: rotating parts!
The running rotor must not be touched.
DANGER
There is a risk of injury by electrical shock!
Live connections must not be touched.