SHORT-CIRCUITING OF THE PHASES
E27 Gearless - Installation and maintenance
5323 en - 2018.04 / c
5.6.2 - Recommendation
Connect the motor using cables of the correct cross-section
Nominal
current per
phase (A)
9.5
12
16
Min. cable
cross-section
(mm²)
1.5
1.5
2.5
The cable shielding must be connected to earth, see section 4.4.
It is the responsibility of the user to connect the motor in accordance with the current legislation and regulations in the country of
use. This is particularly important as regards the size of the cables, the type and size of fuses, the earth or ground connection,
powering down, acknowledging insulation faults and protection against overcurrents.
The table above is given for information only and must under no circumstances be used in place of the current standards.
The recommended cross-sections are given for a single-wire cable, with a maximum length of 10m. Above this, line drops due to
the cable length must be taken into account.
5.7 - Switching status of the microswitches
Contact
Colors of the wires
Brake
released
Microswitch
closed
Connector
fitted onto the
brakes
Cables
supplied by
Leroy-Somer
NC
contact
Black / Grey
Yellow/Grey
YES
NO
Black/Purple
NO
YES
NO
contact
Black/ Dark
Blue
Yellow/Green
YES
YES
Black/Red
NO
NO
6 - SHORT-CIRCUITING OF THE PHASES
The short-circuiting of the phases is not allowed to manage the rescue operation of the lift