System bus (CAN) wiring
3
10
MA DrivePLC DE/EN/FR 1.0
plc014
PES
Drive PLC
GND LOW
HI
CG
CG
LO
LO
HI
HI
CG
CG
LO
LO
HI
HI
120
Ω
0
1
PE
PE
120
Ω
0
Controller 1
1
Controller 2
PES HF screen termination through PE connection
l
Only connect terminals of the same designation.
l
Features of the system cable:
Total cable length
up to 300 m
300 to 1000 m
Cable type
LIYCY 2 x 2 x 0.5 mm
2
CYPIMF 2 x 2 x 0.5 mm
2
Cable type
Twisted pair with screening
Pair 1: CAN-LOW (LO) and CAN-HIGH (HI)
Pair 2: 2 GND
Cable resistance
≤
40
Ω
/km
≤
40
Ω
/km
Capacitance per unit length
≤
130 nF/km
≤
60 nF/km
l
Connection of the bus terminating resistors:
l
One resistor 120
Ω
each on the first and last bus device
l
On the 93XX controller the resistor can be screwed directly under the terminals X4/HI and X4/LO
Features:
l
CAN-based with bus protocol according to CANopen (CAL-based Communication Profile DS301)
l
Bus expansion:
–
25 m for max. 1 Mbit/s baud rate
–
up to 1 km with reduced baud rate
l
Extremely reliable data transmission (Hamming distance = 6)
l
Signal level to ISO 11898
l
Up to 63 bus devices are possible
Show/Hide Bookmarks