To install an adapter, complete the following steps:
Figure 30. Adapter installation
Step 1. Remove the fillers on the rear side of the riser cage.
Step 2. Align and insert an adapter into the slot on the riser card. Make sure you install the adapter into the
right slot.
Notes:
• For the detail connectors on the PCIe riser card, see
“PCIe riser assembly” on page 20
.
• Install one adapter at a time, do not insert two adapters to the riser card at the same time.
After you install an adapter, complete the following steps:
1. Reconnect the cables.
2. Reinstall the PCIe riser assembly (see
“Install the PCIe riser assembly” on page 43
3. Install the top cover onto the server (see
“Install the top cover” on page 54
).
4. Install the server into the rack if necessary.
5. Reconnect power cords and all external cables.
6. If necessary, configure the RAID array using the Setup utility configuration.
Install the flash power module
Use this information to install the flash power module.
To avoid possible danger, read and follow the following safety information.
S002
CAUTION:
The power-control button on the device and the power switch on the power supply do not turn off the
electrical current supplied to the device. The device also might have more than one power cord. To
remove all electrical current from the device, ensure that all power cords are disconnected from the
power source.
.
41
Содержание ThinkSystem SR150
Страница 1: ...ThinkSystem SR150 Setup Guide Machine Type 7Y54 ...
Страница 4: ...ii ThinkSystem SR150 Setup Guide ...
Страница 8: ...vi ThinkSystem SR150 Setup Guide ...
Страница 25: ...Chapter 2 Server components 17 ...
Страница 38: ...30 ThinkSystem SR150 Setup Guide ...
Страница 66: ...58 ThinkSystem SR150 Setup Guide ...
Страница 86: ...78 ThinkSystem SR150 Setup Guide ...
Страница 89: ......
Страница 90: ...Part Number SP47A31795 Printed in Chinese Mainland 1P P N SP47A31795 1PSP47A31795 ...