Recover from a Failed Image Upgrade using TFTP
Use
the
following
procedure
to
recover
from
a
failed
image
upgrade
using
TFTP:
1.
Connect
a
PC
to
the
console
port
of
the
switch.
2.
Open
a
terminal
emulator
program
that
supports
the
Telnet
protocol
(for
example,
HyperTerminal,
SecureCRT,
or
PuTTY)
and
input
the
proper
hostname
or
IP
address
and
the
port
to
connect
to
the
console
interface
of
the
switch.
3.
Reload
the
switch
and
access
the
Boot
Management
menu
by
pressing
Shift + B
when
the
following
message
appears
and
the
dots
are
being
displayed.
4.
Enter
Boot
Recovery
Mode
by
selecting
<R>
.
The
Recovery
Mode
menu
will
appear.
5.
To
start
the
recovery
process
using
TFTP,
select
<T>
.
The
following
message
will
appear:
6.
Enter
the
IP
address
of
the
management
port:
7.
Enter
the
network
mask
of
the
management
port:
8.
Enter
the
gateway
of
the
management
port:
9.
Enter
the
IP
address
of
the
TFTP
server:
10.
Enter
the
file
path
and
the
filename
of
the
image:
After
the
procedure
is
complete,
the
Recovery
Mode
menu
will
be
redisplayed.
Press shift-B for startup menu or shift-R for recovery mode: ...
Performing TFTP rescue. Please answer the following questions (enter 'q'
to quit):
IP addr :
Netmask :
Gateway :
Server addr:
Image Filename:
Содержание ThinkSystem NE1032T
Страница 1: ...Lenovo ThinkSystem NE1032T RackSwitch Installation Guide For Lenovo Cloud Network OS ...
Страница 6: ...6 Lenovo G8296 Installation Guide ...
Страница 14: ...14 NE1032T Installation Guide ...
Страница 18: ...18 NE1032T Installation Guide ...
Страница 19: ... Copyright Lenovo 2017 19 Chapter 2 Switch Components This chapter describes the NE1032T hardware components ...
Страница 32: ...32 NE1032T Installation Guide ...
Страница 78: ...78 NE1032T Installation Guide ...
Страница 94: ...94 NE1032T Installation Guide ...
Страница 100: ...100 NE1032T Installation Guide ...
Страница 120: ...120 NE1032T Installation Guide ...