RAID Level
Your server must have the minimum number of SATA hard disk drives installed
for the supported level of RAID below:
v
RAID Level 0 – Striped disk array
– Two hard disk drives minimum
– Better performance without fault tolerance
v
RAID Level 1 – Mirrored disk array
– Two hard disk drives minimum
– Improved read performance and 100% redundancy
To install a secondary hard disk drive, refer to “Installing a secondary hard disk
drive” on page 43.
Configuring the system UEFI to enable SATA RAID
functionality
This section describes how to configure the system UEFI to enable SATA RAID
functionality.
Note:
Use the arrow keys on the keyboard to make selections.
To enable SATA RAID functionality, do the following:
1.
Start the Setup Utility program. See “Starting the Setup Utility program” on
page 79.
2.
Select
Devices
→
ATA Drives Setup
.
3.
Select
Configure SATA as
and press Enter.
4.
Select
RAID
and press Enter.
5.
Press F10 to save the new settings and exit the Setup Utility program. See
“Exiting from the Setup Utility program” on page 82.
Creating RAID volumes
This section describes how to use the Intel Matrix Storage Manager option ROM
configuration utility to create RAID volumes.
To create RAID volumes, do the following:
1.
Press Ctrl+I when prompted to enter the Intel Matrix Storage Manager option
ROM configuration utility during the server startup.
2.
Use the up and down arrow keys to select
Create RAID Volume
and press
Enter.
3.
Type a proper RAID Volume name in the
Name
field and press Tab.
4.
Use the arrow keys to select a RAID level in the
RAID Level
field and press
Tab.
5.
If appropriate, use the arrow keys to select a Stripe Size in the
Stripe Size
field and press Tab.
6.
Type a volume size in the
Capacity
field and press Tab.
7.
Press Enter to initiate volume creation.
8.
When prompted, press Y to accept the warning message and create the
volume.
9.
Return to step 2 to create additional RAID volumes, or select
Exit
and press
Enter.
Chapter 8. Configuring the server
83
Содержание ThinkServer TS200v
Страница 1: ......
Страница 2: ......
Страница 3: ...ThinkServer TS200v Types 0981 0992 1008 and 1010 Hardware Maintenance Manual ...
Страница 28: ...22 ThinkServer TS200v Types 0981 0992 1008 and 1010 Hardware Maintenance Manual ...
Страница 34: ...28 ThinkServer TS200v Types 0981 0992 1008 and 1010 Hardware Maintenance Manual ...
Страница 84: ...78 ThinkServer TS200v Types 0981 0992 1008 and 1010 Hardware Maintenance Manual ...
Страница 107: ......
Страница 108: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...