7.
To install a new hard disk drive into the blue bracket, flex the sides of the
bracket and align pin
1
, pin
2
, pin
3
, and pin
4
on the bracket with
the corresponding holes in the hard disk drive. Do not touch the circuit board
5
on the bottom of the hard disk drive.
Note:
If you are installing a 2.5-inch hard disk drive, install the hard disk
drive into a 2.5-inch to 3.5-inch hard disk drive tray first and then install the
tray into the blue bracket.
8.
Slide the new hard disk drive with the blue bracket into the drive cage until it
snaps into position.
Figure 29. Installing the hard disk drive into the bracket
Chapter 6. Replacing FRUs
55
Содержание ThinkServer TS200v
Страница 1: ......