2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the
Rack Installation Instructions
that comes with the server.
3. Remove the server cover. See “Removing the server cover” on page 89.
4. If necessary, remove the cooling shroud. See “Removing and reinstalling the cooling shroud” on page
97.
5. Locate the Clear CMOS jumper on the system board. Then, remove any parts and disconnect any
cables that might impede your access to the jumper.
6. Move the Clear CMOS jumper from the default normal position (pin 1 and pin 2) to the short-circuited
position (pin 2 and pin 3).
7. Wait more than 10 seconds and then move the Clear CMOS jumper back to the normal position (pin 1
and pin 2).
8. Reinstall any parts and reconnect any cables. Then, reinstall the server cover. See “Completing the
parts replacement” on page 206.
9. Connect the server to an ac power source and wait about 30 seconds. Then, turn on the server. The
BIOS settings turn to the factory default settings.
2
TMM Enable/Disable jumper (also known as BMC Enable/Disable jumper)
When the TMM Enable/Disable jumper is in the default normal position (pin 1 and pin 2), the server needs
about 30 seconds for the TMM to initialize whenever you connect the server to an ac power source. If you
press the power button on the front of the chassis during this period, the server will not start immediately; it
will start after the TMM initialization finishes.
If you move the TMM Enable/Disable jumper to pin 2 and pin 3, the TMM function is not available and the
server will be directly turned on when you press the power button without waiting for the TMM to be ready.
58
ThinkServer RD440 User Guide and Hardware Maintenance Manual
Содержание ThinkServer RD440
Страница 18: ...6 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 74: ...62 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 98: ...86 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 222: ...210 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 232: ...220 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 246: ...234 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 247: ......
Страница 248: ......