Note:
The option kit for a RAID card is designed for different types of servers and might contain additional
cables that are not required for your server.
Figure 35. Connecting cables from the RAID card to the backplane
To connect cables from the RAID card to the backplane, do one of the following depending on the type of
your RAID card:
• If you are using a ThinkServer RAID 500 Adapter, do the following:
1. Use the mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
1
to the port 0 on the
RAID card. Then, connect the mini-SAS connector
2
to the mini-SAS ports 0-3 on the backplane.
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS
signal cable. Connect the mini-SAS connector
3
to the port 1 on the RAID card. Then, connect the
mini-SAS connector
4
to the mini-SAS ports 4-7 on the backplane.
• If you are using a ThinkServer RAID 700 Adapter, do the following:
1. Use one mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
3
to the ports 3-0 on
the RAID card. Then, connect the mini-SAS connector
4
to the mini-SAS ports 0-3 on the backplane.
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS signal
cable. Connect the mini-SAS connector
1
to the ports 7-4 on the RAID card. Then, connect the
mini-SAS connector
2
to the mini-SAS ports 4-7 on the backplane.
• If you are using a ThinkServer RAID 710 Adapter, do the following:
1. Use the mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
1
to the port 1 on the
RAID card. Then, connect the mini-SAS connector
2
to the mini-SAS ports 0-3 on the backplane.
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS
signal cable. Connect the mini-SAS connector
3
to the port 2 on the RAID card. Then, connect the
mini-SAS connector
4
to the mini-SAS ports 4-7 on the backplane.
Refer to the following topics for information about the connector locations and the power cable connections:
•
“Hot-swap hard-disk-drive backplane” on page 44
•
“RAID card” on page 40
•
“System board components” on page 53
Connecting cables from the RAID card to the expander card, and then from the
expander card to the backplanes
To support more than eight and up to twelve 3.5-inch hard disk drives or up to sixteen 2.5-inch hard disk
drives, your server must have a supported RAID card and an expander card installed. You need to connect
cables from the RAID card to the expander card, and then from the expander card to the backplanes.
Chapter 3
.
Product overview
49
Содержание ThinkServer RD440
Страница 18: ...6 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 74: ...62 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 98: ...86 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 222: ...210 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 232: ...220 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 246: ...234 ThinkServer RD440 User Guide and Hardware Maintenance Manual ...
Страница 247: ......
Страница 248: ......