This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0038
User Action:
Complete the following steps:
1. Check the XCC event log for any fan-, cooling-, or power-related issues.
2. Make sure fan and power supply unit are installed correctly and clean.
3. Make sure that the airflow at the front and rear of the chassis is not obstructed
4. Make sure that the room temperature is within the range of operating specifications.
5. If the problem still exists and XCC event is related to power supply unit, please upgrade power supply
unit with supported specification on server proven plan ( (https://static.lenovo.com/us/en/
serverproven/flex/8721_7893.shtml) ) or adjust power redundant policy in CMM.
6. If the problem still exits after finishing the actions above, please contact Lenovo Support.
•
FQXSPPU0003N: [ProcessorElementName] has Failed with IERR.
This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0042
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or UEFI firmware update that applies to
this processor error.
2. Reboot system.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
•
FQXSPPU0004M: [ProcessorElementName] has Failed with FRB1/BIST condition.
This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST
condition.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0044
User Action:
88
ThinkSystem SN550 V2 Messages and Codes Reference
Содержание 7X16
Страница 1: ...ThinkSystem SN550 V2 Messages and Codes Reference Machine Type 7X16 ...
Страница 4: ...ii ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 140: ...136 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......