User Action:
1. Remove A/C from the server and reseat all drives, backplanes, RAID adapters, expanders (if any), and
cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the problem persists, please contact technical support.
•
FQXPMSD0005M: self-test completed having the servo (and/or seek) test element of the test failed.
Severity: Error
User Action:
1. Remove A/C from the server and reseat all drives, backplanes, RAID adapters, expanders (if any), and
cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the problem persists, please contact technical support.
•
FQXPMSD0006M: self-test completed having the read element of the test failed.
Severity: Error
User Action:
1. Remove A/C from the server and reseat all drives, backplanes, RAID adapters, expanders (if any), and
cables.
2. Ensure device firmware is at the latest level.
3. Retry the test.
4. If the problem persists, please contact technical support.
•
FQXPMSD0007M: Hard Drive(s) not found
Severity: Error
User Action:
1. Remove A/C from the server and reseat all drives, backplanes, RAID adapters, expanders (if any), and
cables.
2. Ensure device firmware is at the latest level.
3. Verify that the same Error is present in BMC or OneCLI inventory log.
4. Retry the test.
5. If the problem persists, please contact technical support.
•
FQXPMSD0008M: UEFI is not ready for LXPM to send command to test hard drive.
Severity: Error
User Action:
1. Reboot system and run the test again.
2. If this message is still reported, please run the latest version of SMART tool on OS which is open
source tool and could be downloaded from website to check hard drive status.
3. If the problem persists, please contact technical support.
•
FQXPMSD0009M: Device error is occurred when LXPM send command to test hard drive.
.
XClarity Provisioning Manager events
191
Содержание 7X16
Страница 1: ...ThinkSystem SN550 V2 Messages and Codes Reference Machine Type 7X16 ...
Страница 4: ...ii ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 140: ...136 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SN550 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......