1.7. W4 Wireless Controller - Connections, buttons and LEDs
Wireless Board (W4)
Service App QR Code
* Allow users to quickly find the service app
2-Port IP Switch
BACnet IP
* Automatic firmware updates
* Allows daisy-chain connection
USB port
* Firmware Updates
* System Logs and Reports
* Configuration save/copy
Wireless Gateway Connector
* Connects to unit gateway (coax)
* Allows app and sensor connections
BACnet MS/TP
* Standard on all CORE Unit Controllers
* New objects supported
Pair Button and LED
* Pressing button allows
pairing to App.
* LED indicates pairing status - solid
blue indicates either BLE is booting up
or mobile device is already connected.
Green indicates ready for connection.
Blinking blue indicates in pairing mode.
Reset Button and Heart
Beat LED
* Reset Button for the W4 control
* Blinking LED indicates W4 power
Cloud / IP Button and LED
* Button not used at this time
* LED indicates BACnet and cloud
connectivity. Red LED indicates not
connected and green indicates connected.
Figure 3. W4 Controller Interfaces
1.8. Cloud Firmware Updates
• Internet connection is required
• On-demand or automatic
• CORE Unit Controller connects to cloud via IP (Ethernet)
• Can check on demand or nightly
>
Configurable via app
> Default: On demand
• Free updates
• Updates are also available via USB
2. Network Types
The following are the types of communication network types
supported.
Table 3. Network Types
Screen Label
Network Type
LON
LonTalk
BACNET
BACnet MS/TP and IP
LCONN
L-Connection
RTU
Rooftop Unit stand-alone mode status
indicator
3. Unit Operation
This section describes the display and control buttons, how
to configure the unit, and how to read stored configuration
data, status, and alarms.
The CORE Unit Controller is an input and output junction
point. If in the thermostat mode, thermostat inputs at P297
result in an output to unit components. If the heartbeat LED
is not flashing, see ”Table 1. LED Operation Indicators” on
page 5 for heartbeat operation. If the display shows
an alarm. If the thermostat input indicating lights are not
responding appropriately, check the thermostat or a DDC
control acting as thermostat inputs into P297.
Basic cooling and heating functions may be energized to test
major unit components by using the CORE Unit Controller
testing function or by using jumper wires on the Field Wiring
Termination plug P297.
Содержание Core Unit Controller
Страница 75: ...75 Table 15 J297 TSTAT Inputs and Service Relays Table 16 J298 Analog Sensors Table 17 J378 Duct Sensors ...
Страница 77: ...77 Table 22 J383 Ultra Evaporators Table 23 J384 Economizer ...
Страница 80: ...80 Table 32 J393 Gas Heat Table 33 J393 Electric Heat Table 34 J394 ReHeat Table 35 J388 C Box ...
Страница 81: ...81 Table 36 J389 C Box Table 37 J395 Power In Table 38 J358 MODUS Vs COMPR Table 39 J413 Modbus ...
Страница 85: ...85 Table 54 J406 A12 M4 Control J406 A12 Table 55 J374 Versions 1 through 4 ...
Страница 86: ...86 Table 56 J10 GV1 S18 J10 S18 Table 57 J408 GV1 S47 J408 Table 58 J412 MODUS 2 Table 59 J411 MODUS 1 ...
Страница 91: ...91 ...