Chap 3.9 Spare Parts listing  

 

  

COMPACT PRO AND PRO PLUS 

  

Code 

Description 

Explosion view 

276311A74 

REMOTE COTROL 

01M0263 

OUTLET AIR VOLUTE 

03M0018GU17  UNIT HOOD 

03M0049GU31  SCREW RUBBER COVER 

05M0076 

STEP MOTOR 

18M0130 

LED BASE 

03M0035GT05 

FIXED GRILLE 

03M0023GT05 

CONTROL BOARD 

592987A 

LED FACIA STRIP  

21M0137 

COMPRESSOR INSULATION UNIT SIZE 21 

10 

21M0138 

COMPRESSOR INSULATION UNIT SIZE 24 

10 

271968A 

COMPRESSOR GASKET 

10 

276274A 

COMPRESSOR GOLDSTAR GK080PAA UNIT SIZE 21 

10 

276269A 

COMPRESSOR GOLDSTAR GK113PAB UNIT SIZE 24 

10 

277582A 

KLIXON COVER 

10 

276276A 

KLIXON COMPR GOLD MRA 12009-12026 UNIT SIZE 21 

11 

276295A 

KLIXON COMPR GOLD MRA 12130-12026 UNIT SIZE 24 

11 

03M0278GS33 

FLOAT 

12 

03M0024NN17 

MICRO SWITCH SUPPORT 

12 

275998A 

MICRO SWITCH 

12 

275999A 

MICRO SWITCH TRIGGER 

12 

05M0194 

DRAIN PUMP 

13 

281692B72 

CONDENSATE DISTRIBUTOR 

14 

23M0114 

CENTRIFUGAL FAN 

15 

275971A 

CAPACITOR 4mF 

16 

591908A85F 

ELECTRONIC BOARD UNIT SIZE 21 cooling only 

17 

591908A85H 

ELECTRONIC BOARD UNIT SIZE 21 heating 

17 

591908A11F 

ELECTRONIC BOARD UNIT SIZE 24 cooling only 

17 

591908A11H 

ELECTRONIC BOARD UNIT SIZE 24 heating 

17 

23M0075 

RADIAL FAN 

18 

03M0045GS33 

EVAPORATOR FAN PLUG 

19 

13S0380 

INDUCTOR 250mH 500mA 

20 

03M0012GT37 

INTERNAL AIR FILTER 

21 

255546A70 

POWER CABLE 

23 

275964A 

CAPACITOR 25mF UNIT SIZE 21 

24 

276309A 

CAPACITOR 30mF UNIT SIZE 24 

24 

03M0017GT05 

SUCTION GRILLE 

25 

599918A 

EXTERNAL GRID 

29 

01M0259 

CONDENSATE DISPOSAL GROUP 

31 

24M0280 

EVAPORATOR   

32 

256413A 

CONDENSER 

33 

598868A 

4 WAYS VALVE UNIT SIZE 21 

35 

598869A 

4 WAYS VALVE UNIT SIZE 24 

35 

02M0087BO34 

AIR INLET PIPE 

36 

01M0258 

AIR OUTLET PIPE 

37 

03M0083BP35 

INNER FLANGES 

38 

599919A1 

GRILLE FIXING CHAINS 

40 

599919A1 

GRILLE RETAINING SPRINGS 

41 

  

PRO PLUS MODEL ONLY 

 

Содержание Compact Pro

Страница 1: ...INSTALLATION OPERATING MAINTENANCE MANUAL Compact Pro...

Страница 2: ...ning unit You have bought one of the best air conditioners available today Follow the instructions given in this booklet to obtain the very best performance from your air conditioner and to enjoy a fr...

Страница 3: ...nstallation of Wall Mounted Controller page 17 Chap 3 USE AND MAINTENANCE for the user 3 1 Important Recommendations page 26 3 2 Names of parts page 26 3 2 1 List of Units page 26 3 2 2 Description of...

Страница 4: ...conditioner is installed by personnel lacking the necessary qualifications and specialization this invalidates the warranty CHAP 3 USE AND MAINTENANCE by user Contains all information and instructions...

Страница 5: ...its as well as all the precautions suggested by good sense and by the safety regulations in effect in your country CHAP 1 2 SYMBOLS The pictograms in the next chapter provide the necessary information...

Страница 6: ...t at 35 C b s in heating mode Air entering the inside unit at 21 C b s and 19 C b u with air entering the outside unit at 7 C b s and 6 C b u 1 3 4 The air conditioner should be used for the exclusive...

Страница 7: ...UPSIDE DOWN 1 4 2 The packing is made of suitable material and is done by expert personnel Receipt and The units are delivered complete and in perfect condition however we suggest that you perform the...

Страница 8: ...ce that wouldinterferewithcorrectoperation of the unit It must be possible to leave room around the unit for any maintenance operations that may be necessary The air conditioner must be installed on a...

Страница 9: ...es in walls are special drills called core borers with very high twisting torque and adjustable rotation speed depending on the diameter of the hole to be drilled To prevent the creation of large amou...

Страница 10: ...wall should be inspected carefully to determine the best possibleanchorageand typeofboltssuitableforparticular situations Warning The manufacturer is not liable in case of underestimation of the stru...

Страница 11: ...g 5 Caution make sure in this case that the water expelled outward does not damage or disturb persons or property During the winter this type of drainage may cause sheets of ice to form 2 3 3 After dr...

Страница 12: ...l with 4 anchor bolts with a diameter of 6 mm 2 3 4 The air conditioner is equipped with a power supply cable Power supply and plug Connection Ifitisinstallednearanoutlet youneedonlyplugitin In this c...

Страница 13: ...it into position especially at high level CHAP 2 4 PREPARATION FOR ASSEMBLY INSTALLATION WALL TOP PART AT HIGH LEVEL 2 4 1 The air conditioner is assembled in the factory ready to Introduction be inst...

Страница 14: ...ep step motor of the grating Fit the casing back on the air conditioner carefully taking care to hold the wires for the step step motor to one side so that they do not interfere with the inner part of...

Страница 15: ...he LEDs lighting up at once and blinking ten times as well as by an acoustic signal At this time you can adjust the temperature reading on the room temperature sensor This correction is important if t...

Страница 16: ...After eliminating the malfunction the service personnel will take care of closing the evacuation tube CHAP 2 6 PERIODICAL MAINTENANCE Air conditioners of this type do not require any particular routi...

Страница 17: ...fectly horizontal or at the most having a slight inclination toward outside Put the 130 mm pipe into the hole after you cut it according to the wall thickness ATTENTION the pipe supplied with the kit...

Страница 18: ...E INSTRUCTIONS IN THIS MANUAL Themanufacturerhastherightofmodifyingtheunit atanytime whilstmaintainingthe mainfeatures described in this manual During installation or maintenance it is necessary to fo...

Страница 19: ......

Страница 20: ...ructions may cause malfunction of the device and warranty won t be valid anymore B1000 can work in stand alone or in a network by changing the set of switches Positioning of B1000 The card must be pla...

Страница 21: ...box by taking the screw on the right side out B To fix the box to the wall use the screws that are given in the pack C Attention Be very careful in order not to damage the card and its components dur...

Страница 22: ...control box push the trigger on the left side and lift rotating towards the other side Positioning If you put the control farer than 2m from the conditioner you have to take a loner wire In this case...

Страница 23: ...75 230v 50Hz given K2 CAN BUS mains 1 CAN L 2 CAN H 3 GND 4 Screening Screened cable 3x0 34 K3 Serial for the air conditioner 1 TX 2 GND 3 RX Given Not extendible K4 Contact occupied room 1 Contact r...

Страница 24: ...s specified in the instructions if you use the mains connection DIP SWITCH CONFIGURATION On the board there are 12 microswitches dip switch that are subdivided in two groups of 4 S1 and 8 S2 selectors...

Страница 25: ...model In mails Stand alone 1 The address of the board on CAN bus has to be unique and unequivocal the coding is expressed on the basis 2 2 The function of this selector is active only for the configu...

Страница 26: ...2 C and t set C Temp pilot light it lights up when it is fixed a temperature 2 C lower than the set one D Temp pilot light it lights up when it is fixed a temperature 2 C higher than the set one When...

Страница 27: ...h the remote control Once the machine is started through the remote control in compliance with the above data you have to press the button placed on the power board see picture to store on the Eprom t...

Страница 28: ......

Страница 29: ...f airflow 3 Motor operated air baffles for upward airflow 4 Alarm display console 5 Air intake grating 6 Grips for removal of air filter 7 Rubber hose with cap on end for evacuation of 8 condensation...

Страница 30: ...collection points provided by the local authorities for this type of waste REPLACE BOTH BATTERIES AT THE SAME TIME To insert the batteries remove the spring latch cover on the back of the remote contr...

Страница 31: ...witch off or unplugging the machine from the mains 3 4 4 By means of this button the machine is automatically Wellbeingmode regulated in order to create an optimal comfort tempera Automatic ture in th...

Страница 32: ...ing pump HP heatpump To select this mode press button T4 operating mode selection switch until the sun symbol appears on the display First set the desired temperature and fan speed see the specific pa...

Страница 33: ...o the effective room temperature As the room temperature nears the setting fan speed is reduced automatically When the unit is operating in dehumidification mode fan speed adjustment is not possible a...

Страница 34: ...ed Night comfort mode operation is not available for dehumidifying only Night comfort mode operation can be halted at any time ideally when you wake up in the morning by pressing button T3 again At th...

Страница 35: ...ime when you want program 2 to start Every time you press one end of the toggle button the time setting increases or decreases by 30 minutes g Press button T6 Time and Program Setting as many times as...

Страница 36: ...3 5 MAINTENANCE Your air conditioner has been designed to reduce operations of routine maintenance to a minimum and ensure that they can be performed easily by any user The only operations required a...

Страница 37: ...nctions This is to safeguard the compressor When heating on versions with the heating pump the machine does not start emitting heat until a few minutes after the compressor starts If the fan should go...

Страница 38: ...re has been an increase in the heating or cooling load for example a door or window has been left open or a device that dissipates a large amount of heat has been installed in the room what to do make...

Страница 39: ...999A MICRO SWITCH TRIGGER 12 05M0194 DRAIN PUMP 13 281692B72 CONDENSATE DISTRIBUTOR 14 23M0114 CENTRIFUGAL FAN 15 275971A CAPACITOR 4mF 16 591908A85F ELECTRONIC BOARD UNIT SIZE 21 cooling only 17 5919...

Страница 40: ......

Страница 41: ...www lennoxuk com Lennox UK Cornwell Business Park Salthouse Road Brackmills Northampton NN4 7EX Tel 01604 669100 Fax 01604 669150 info uk lennoxeurope com 07 2005...

Отзывы: