2.3.5
After checking again that the fastening bracket is securely
Fitting the unit
fastened to the wall, and that any necessary preparations
on bracket
for electric connection and condensate drainage have been
made, you can fasten the air conditioner to its supporting bracket.
Lift it up holding the sides of the bottom (see fig. 13).
To facilitate the operation of fastening it to the bracket, tilt it slightly
toward you.
To make the electrical connection and fasten the drainpipe, place a
wedge between the air conditioner and the wall (see fig. 14).
After these operations have been carried out, the air conditioner
can be pushed firmly against the wall so that the bottom hook
catches.
When you have finished, inspect carefully to make sure there are
no fissures at the back of the air conditioner (the insulating gasket
must fit firmly against the wall) particularly in the zone where air
enters and leaves the machine.
WARNING- Please check the weight of the unit as it may
require 2 people to lift it into position, especially at high
level.
CHAP. 2.4
PREPARATION FOR ASSEMBLY/INSTALLATION WALL
TOP PART AT HIGH LEVEL
2.4.1
The air conditioner is assembled in the factory ready to
Introduction
be installed low on the wall.
The air outlet, in this case, is at the top of the air conditioner with the
recycle grating and control panel. In order to prepare the product for
installation on the top part of the wall, follow the instructions below.
2.4.2
Removal of front
casing
Note: if the air conditioner has not been installed on the wall yet,
place it on its back. To not apply heavy pressure to the bottom of the
device as this could dent or scratch the casing.
Use a small blade screwdriver to remove the horizontal strips on the
casing, applying gentle leverage in the slits along the sides. (see fig.
15). Take care not to scratch the strips or casing with the
screwdriver point.
Unscrew the 8 self-threading screws that fasten the casing to the air
conditioner.
Lift the casing off carefully, pulling it toward you by about 50 cm (see fig.
16).
Disconnect the fastener on the right that fastens the wires to the airflow
deviation baffle adjustment motor (see fig. 17). Now you can remove the
casing completely.