background image

10

FOR YOUR SAFETY READ BEFORE LIGHTING

A.

This heater has a pilot which must be lit by hand. When
lighting the pilot, follow these instructions exactly.

B.

BEFORE OPERATING smell all around the heater area for gas.
Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s phone. 
Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C.

Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, do
not try to repair it, call a qualified service technician. Forced or
attempted repair may result in a fire or explosion.

D.

Do not use this heater if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.

23.0 LIGHTING INSTRUCTIONS

1. Stop! Read the safety information above.

2. Make sure manual shut-off valve is fully open.

3. Open the glass facia.

4. Depress control knob in and turn clockwise                     to the
“OFF” position ( Figure 7 ).

5. Wait 5 minutes to clear out any gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Follow the safety instructions in “What
to do if you smell gas” under section ‘B’ above. If you do not smell gas,
go to next step.

6. The pilot is located on the left side behind the burner (Figure 9).

7. Depress control knob in and turn counterclockwise
to the “SPARK” position ( Figure 8 ) and hold there for a few seconds.

Note: If you are running the heater for the first time or after an extended
period of non use it will be necessary to press the control knob all the
way in for 30 seconds to allow air to bleed out of the gas piping.

8. Continue turning counterclockwise                        through the spark
click to the PILOT light position, ensuring the pilot has lit. If not, turn the
knob fully clockwise, and repeat.

9. Hold the control knob in for a further 10 seconds to prevent the flame
failure detector from shutting off the gas while the probe is warming up.

10. Release the control knob while turning counterclockwise
to the preferred setting. Close  the glass facia.

• If the knob does not pop out when released, stop and immediately call
your service technician or gas supplier.

• If the pilot will not stay lit after several tries, depress and turn the gas
control knob clockwise                      to “OFF”and wait 30 seconds.
Depress and turn knob counterclockwise                       to “SPARK” and
ignite the heater again. If your pilot does not relight depress and turn
control knob clockwise                      to “OFF” and call your service
technician or gas supplier.

11. Wait 30 seconds before readjusting the heater when the control knob
has been turned down to a lower setting.

24.0 TO TURN OFF GAS TO APPLIANCE

2. Depress and turn control knob clockwise                      to the “OFF”
position (Figure 8). Close  the control access panel.

1. Open the glass facia.

Figure 8 : Control knob. This is located
behind the glass facia panel of the appliance.

Figure 9: Pilot unit. This is located behind the
burner, on the left-hand side of the appliance.

Figure 9

Figure 8

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

WARNING

Содержание Radium-NG

Страница 1: ...l retain heat for a while after shutting off the appliance Severe burns may result Carefully supervise children in the same room as appliance Duetohightemperatures theapplianceshouldbelocatedoutoftraf...

Страница 2: ...omer 8 17 0 Servicing 8 18 0 Servicing the Burner 8 19 0 Pilot Assembly 8 20 0 Catalysts 9 21 0 Testing for Firebox Leakage 9 22 0 Cleaning 9 23 0 Lighting Instructions 10 24 0 To Turn off gas to Appl...

Страница 3: ...h 248 CMR c Unvented natural gas fired space room heaters shall be installed in accordance with their listings and the manufacturer s instructions Proper clearances to combustibles shall be maintained...

Страница 4: ...copy of 527 CMR 30 upon sale of the unit Please refer to section 4 0 on page 2 of this manual This Lennox Hearth Products unvented gas room heater is certified by OMNI Test Laboratories Inc to ANSI Z...

Страница 5: ...e appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important...

Страница 6: ...e fixings screw the mounting plate to the wall via the four mounting holes The heater may then be hung onto the mounting plate The bottom of the heater may be secured onto the lower mounting studs usi...

Страница 7: ...ge 2 of these instructions The pressure should be checked with the gas heater burning and the control set to high flame The pressure regulator on manual models is preset and locked to avoid tampering...

Страница 8: ...he pilot lint gauze and clean with a soft brush Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot head Check the aeration holes are free from lin...

Страница 9: ...remove the glass facia as described in section 15 0 The catalysts are located on the top of the internal firebox and can be removed be unscrewing the retaining nuts securing the clamping plate Remove...

Страница 10: ...ress control knob in and turn counterclockwise to the SPARK position Figure 8 and hold there for a few seconds Note If you are running the heater for the first time or after an extended period of non...

Страница 11: ...t flame shrinks when fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all pipework is adequately sized Check...

Страница 12: ...re 12 Visual check for correct pilot flame 4 off burner installation positions 27 0 POSITIONING OF FIELD REMOVABLE PARTS Damper Fixing hole Lower Damper fixing components Upper Damper fixing component...

Страница 13: ...e The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temper...

Страница 14: ...Supervise con atenci n a los ni os que est n en la misma habitaci n que el aparato Debido a las altas temperaturas generadas el aparato debe ubicarse en un lugar con poco tr nsito alejado de muebles y...

Страница 15: ...21 20 0 Catalizadores 22 21 0 Comprobaci n de fugas de la c mara de combusti n 22 22 0 Limpieza 22 23 0 Instrucciones de encendido 23 24 0 C mo cerrar el paso de gas al aparato 23 25 0 Gu a de soluci...

Страница 16: ...nto de ox geno ODS y contar con la aprobaci n establecida en 248 CMR c Los calentadores de gas natural sin salida de humos deben instalarse seg n sus especificaciones y las instrucciones del fabricant...

Страница 17: ...onar a cada comprador una copia de 527 CMR 30 en el momento de la venta de la unidad Consulte la secci n 4 0 en la p gina 2 de este manual Este calentador de gas sin salida de humos de Lennox Hearth P...

Страница 18: ...ared revestida de cart n yeso o en una pared de armaz n de madera debe confirmarse la integridad de la pared y su capacidad para soportar el peso del aparato Es importante en estas circunstancias no d...

Страница 19: ...Primero localice los montantes y usando los accesorios de sujeci n adecuados atornille la placa de montaje a la pared a trav s de los cuatro orificios de montaje Ahora se puede colgar el calentador e...

Страница 20: ...endido y el control puesto en llama alta El regulador de presi n de los modelos manuales est preajustado y bloqueado para evitar su manipulaci n indebida Si la presi n no es la especificada en la secc...

Страница 21: ...anche el filtro de malla del piloto y l mpiela con un cepillo suave Limpie el exterior del conjunto del piloto con un cepillo suave y sople por los orificios de las llamas en el cabezal del piloto Com...

Страница 22: ...catalizadores se encuentran encima de la c mara de combusti n interna y pueden retirarse desatornillando las tuercas de retenci n de la placa de sujeci n Retire el catalizador y las juntas y des chel...

Страница 23: ...ontrario a las agujas del reloj a la posici n SPARK Figura 8 y mant ngala presionada en esa posici n durante unos segundos Nota Al encender el calentador por primera vez o despu s de un periodo prolon...

Страница 24: ...I DOBLE EL TERMOPAR PARA HACER QUE EL PILOTO SE MANTENGA ENCENDIDO La llama del piloto se reduce cuando el Flujo defectuoso de gas al calentador compruebe la presi n con el calentador en Alto calentad...

Страница 25: ...ma del piloto 4 posiciones de instalaci n del quemador 27 0 UBICACI N DE PIEZAS SUSTITUIBLES IN SITU Amortiguador Orificio de fijaci n Componentes de fijaci n del amortiguador inferior Componentes de...

Страница 26: ...e ser sometido a un uso normal El Producto est dise ado para usarse con gas natural o propano exclusivamente El uso de combustibles convencionales como madera carb n o cualquier otro combustible s lid...

Отзывы: