background image

1110 West Taft Avenue • Orange, CA 92865

NOTE:  DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Lennox reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local dealer or distributor for fireplace code information.

LENNOX HEARTH PRODUCTS

P/N 850,054M REV. NC 04/2007

Lennox Hearth Products Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Lennox Hearth Products ("LHP") warrants your gas fireplace, appliance, stove or insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. After
installation, if any of the components manufactured by LHP in the Product are found to be defective in materials or workmanship during the twenty year warranty period and while the
Product remains at the site of the original installation, LHP will, at its option, replace or repair the defective components. LHP will also pay for reasonable labor costs incurred in replacing
or repairing such components for a period of one year from the date of installation. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Warranty as described herein.

EXCLUSIONS AND LIMITATIONS

This Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instructions accompanying
the Product and in compliance with all applicable installation and building codes and good trade practices. If repair or replacement is not commercially practical, LHP will, at its option,
refund the purchase price of the LHP Product.

The firebox and enclosure are warranted for twenty (20) years from the date of installation as follows: First year - parts at no charge and reasonable labor charges. Second through fifth
year - parts only at no charge. Sixth through twentieth year - parts only at 50% of the then current list price. Vent components, brass components, paint, optional accessories and optional
glass doors are excluded from this Limited Warranty. A separate limited warranty is available from LHP for optional glass doors manufactured by LHP. The following components are
NOT warranted for 20 years but are warranted as follows:

Controls - repair or replacement for one year from the date of installation.
Burner - repair or replacement for one year from the date of installation.
Glass Components - repair or replacement for one year from the date of installation. Ceramic glass is warranted against thermal breakage only for a period of

two years from date of installation.

Gaskets - repair or replacement for one year from the date of installation.
Logs - repair or replacement for one year from the date of installation.
Catalyst - two years parts and labor, 3-5th year, parts only from the date of installation.

We will not be responsible for: (a) damages caused by accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or unauthorized alteration or repair
of the Product affecting its stability or performance (The Product must be subject to normal use. The Product is designed to burn either natural or propane gas only. Burning conventional
fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures and will result in a fire hazard); (c) damages caused by failing to
provide proper maintenance and service in accordance with the instructions provided with the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application
of the Product. 

This Limited Warranty covers only parts and labor as provided herein. In no case shall LHP be responsible for materials, components or construction which are not manufactured or
supplied by LHP or for the labor necessary to install, repair or remove such materials, components or construction. All replacement or repair components will be shipped F.O.B. the
nearest LHP factory.

LIMITATION ON LIABILITY
It is expressly agreed and understood that LHP's sole obligation and purchaser's exclusive remedy under this warranty, under any other warranty, expressed or implied, or
in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein. In no event shall LHP be liable for any incidental or consequential
damages caused by defects in the Products, whether such damage occurs or is discovered before or after replacement or repair, and whether such damage is caused by
LHP's negligence. LHP has not made and does not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition of fitness
for a particular use or purpose.

We make no express warranties except as stated in this Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this Limited Warranty or to create for us any other obligation or liability in connection with the Product. Some states and provinces do not
allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited
Warranty are in addition to and not a modification of or substraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

LHP reserves the right to investigate any and all claims against this Limited Warranty and to decide upon method of settlement.

LHP NOT RESPONSIBLE FOR WORK DONE WITHOUT WRITTEN CONSENT

To receive the benefits and advantages described in this Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by LHP. Contact LHP at the
address provided herein to obtain a listing of approved dealers. LHP shall in no event be responsible for any warranty work done by a contractor that is not approved without first obtaining
LHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this Warranty to be valid, LHP must be notified of the claimed defect in writing as soon as reasonably possible after the
defect is discovered. Notices should be directed to LHP, attention Customer Service Department, 1110 West Taft Avenue, Orange, CA 92865. Claims in writing should include the date
of installation and a description of the defect.

Содержание Radium-NG

Страница 1: ...l retain heat for a while after shutting off the appliance Severe burns may result Carefully supervise children in the same room as appliance Duetohightemperatures theapplianceshouldbelocatedoutoftraf...

Страница 2: ...omer 8 17 0 Servicing 8 18 0 Servicing the Burner 8 19 0 Pilot Assembly 8 20 0 Catalysts 9 21 0 Testing for Firebox Leakage 9 22 0 Cleaning 9 23 0 Lighting Instructions 10 24 0 To Turn off gas to Appl...

Страница 3: ...h 248 CMR c Unvented natural gas fired space room heaters shall be installed in accordance with their listings and the manufacturer s instructions Proper clearances to combustibles shall be maintained...

Страница 4: ...copy of 527 CMR 30 upon sale of the unit Please refer to section 4 0 on page 2 of this manual This Lennox Hearth Products unvented gas room heater is certified by OMNI Test Laboratories Inc to ANSI Z...

Страница 5: ...e appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important...

Страница 6: ...e fixings screw the mounting plate to the wall via the four mounting holes The heater may then be hung onto the mounting plate The bottom of the heater may be secured onto the lower mounting studs usi...

Страница 7: ...ge 2 of these instructions The pressure should be checked with the gas heater burning and the control set to high flame The pressure regulator on manual models is preset and locked to avoid tampering...

Страница 8: ...he pilot lint gauze and clean with a soft brush Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot head Check the aeration holes are free from lin...

Страница 9: ...remove the glass facia as described in section 15 0 The catalysts are located on the top of the internal firebox and can be removed be unscrewing the retaining nuts securing the clamping plate Remove...

Страница 10: ...ress control knob in and turn counterclockwise to the SPARK position Figure 8 and hold there for a few seconds Note If you are running the heater for the first time or after an extended period of non...

Страница 11: ...t flame shrinks when fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all pipework is adequately sized Check...

Страница 12: ...re 12 Visual check for correct pilot flame 4 off burner installation positions 27 0 POSITIONING OF FIELD REMOVABLE PARTS Damper Fixing hole Lower Damper fixing components Upper Damper fixing component...

Страница 13: ...e The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temper...

Страница 14: ...Supervise con atenci n a los ni os que est n en la misma habitaci n que el aparato Debido a las altas temperaturas generadas el aparato debe ubicarse en un lugar con poco tr nsito alejado de muebles y...

Страница 15: ...21 20 0 Catalizadores 22 21 0 Comprobaci n de fugas de la c mara de combusti n 22 22 0 Limpieza 22 23 0 Instrucciones de encendido 23 24 0 C mo cerrar el paso de gas al aparato 23 25 0 Gu a de soluci...

Страница 16: ...nto de ox geno ODS y contar con la aprobaci n establecida en 248 CMR c Los calentadores de gas natural sin salida de humos deben instalarse seg n sus especificaciones y las instrucciones del fabricant...

Страница 17: ...onar a cada comprador una copia de 527 CMR 30 en el momento de la venta de la unidad Consulte la secci n 4 0 en la p gina 2 de este manual Este calentador de gas sin salida de humos de Lennox Hearth P...

Страница 18: ...ared revestida de cart n yeso o en una pared de armaz n de madera debe confirmarse la integridad de la pared y su capacidad para soportar el peso del aparato Es importante en estas circunstancias no d...

Страница 19: ...Primero localice los montantes y usando los accesorios de sujeci n adecuados atornille la placa de montaje a la pared a trav s de los cuatro orificios de montaje Ahora se puede colgar el calentador e...

Страница 20: ...endido y el control puesto en llama alta El regulador de presi n de los modelos manuales est preajustado y bloqueado para evitar su manipulaci n indebida Si la presi n no es la especificada en la secc...

Страница 21: ...anche el filtro de malla del piloto y l mpiela con un cepillo suave Limpie el exterior del conjunto del piloto con un cepillo suave y sople por los orificios de las llamas en el cabezal del piloto Com...

Страница 22: ...catalizadores se encuentran encima de la c mara de combusti n interna y pueden retirarse desatornillando las tuercas de retenci n de la placa de sujeci n Retire el catalizador y las juntas y des chel...

Страница 23: ...ontrario a las agujas del reloj a la posici n SPARK Figura 8 y mant ngala presionada en esa posici n durante unos segundos Nota Al encender el calentador por primera vez o despu s de un periodo prolon...

Страница 24: ...I DOBLE EL TERMOPAR PARA HACER QUE EL PILOTO SE MANTENGA ENCENDIDO La llama del piloto se reduce cuando el Flujo defectuoso de gas al calentador compruebe la presi n con el calentador en Alto calentad...

Страница 25: ...ma del piloto 4 posiciones de instalaci n del quemador 27 0 UBICACI N DE PIEZAS SUSTITUIBLES IN SITU Amortiguador Orificio de fijaci n Componentes de fijaci n del amortiguador inferior Componentes de...

Страница 26: ...e ser sometido a un uso normal El Producto est dise ado para usarse con gas natural o propano exclusivamente El uso de combustibles convencionales como madera carb n o cualquier otro combustible s lid...

Отзывы: