33
iCON grade, System Installation
Installing the shock mount
The shock mount is bolted to the mounting bracket with the three 16 mm
bolts that are supplied with it.
•
Put the three 16 mm bolts in the rubber shock absorber block, and
then place the block in the shock mount. Align the block so that all
three bolts go through the shock mount and through the mounting
plate, and fasten the shock mount to the mounting bracket with the
three 16 mm lock nuts.
•
Fasten the bottom quick mount bracket to the shock absorber block
with two bolts. The bracket must be mounted so that the grove in the
middle of the bracket is facing the same way as the top clamp opens.
•
Fasten the top quick mount bracket to the Power Mast with four
bolts. The bracket must be mounted so that the open end is facing
the same way as the connectors on the Power Mast.
Top Clamp
Handle
Shock mount
a) - Rubber shock
absorber block
b) - Bottom quick
mount bracket
c) - Top quick mount
bracket
The 3 units above (a, b and c) assembled to one single unit.