iCON grade, Calibrating the System
Interface type
Set the hardware used for hydraulic control.
Left
When selecting interface type
Junction Box
the following menu options
will appear:
The options are:
•
Junction Box
For traditional hydraulic valve
installations.
•
CAT® Interface
For controlling the blade
using the CI-14 on Cater-
pillar® machines with elec-
tronic joysticks.
•
CAT® SEA
For controlling the blade
through CAN-bus messages
on ARO-prepared Cater-
pillar® machines with SEA-
key enabled.
•
John Deere IGC
For controlling the blade
through CAN-bus messages
on IGC-enabled John Deere
machines.
The next two menu items on
Dozers and three menu items for
Graders set the hydraulic valve
type. Set this for Left, Right, and
Side (for Graders).
The possible valve types are:
•
Danfoss
•
Voltage PNP
•
Voltage NPN
•
Proportional PNP
•
Proportional NPN
(Select proportional NPN for
Pilot valves)
•
On/Off NPN
(Select frequency: 2-7 Hz)
•
On/Off PNP
(Select frequency: 2-7 Hz)