iCON grade, Deadband and Gain
4
Deadband and Gain
DEADBAND
The deadband controls the precise motion of machine hydraulics. These
values do not correspond to accuracy, but to hydraulic speeds. These
values should not be confused with overall machine performance and/or
precision.
Adjust the deadband for each sensor. This is done in the adjust menu for
each sensor.
GAIN
This is the scaling (sensitivity) of hydraulic speeds for each of the sensors.
These values should be measured at the initial calibration but can be fine-
tuned as needed (heavy or rough material, wet dirt, fine grading, etc.).
To enter
Gains
select the appropriate
Sensor Select
buttons to open up
the available sensors. Select appropriate sensor and then the
or
key (depending on left or right side) to enter the
Adjust
Menu.
Adjust the gain of the hydraulic system for each sensor. This is done by
pressing the
2s
button in the
Adjust
menu for each sensor. This will
control the hydraulics
Upwards
for two seconds. Revert if necessary
using the
Revert
button.
Please follow the on-screen instructions!
Elevation:
Press the
2s
button to adjust the value so that it corresponds to the
distances below. A simple tape-measure or ruler can be used to gauge the
actual blade movement (taking great care around the machine). For
example, after pressing the
2s
button, the blade should move approxi-
mately 15 cm for GPS.
Note that these values are indicative only, and different operators may
prefer slightly faster or slower settings.
Sensor
Grader
GPS
1.0 cm
Laser
0.7 cm
Cross slope
0.3 %
Tracker
0.5 cm
Sideshift
2.0 cm
Sensor
Grader
Laser/Sonics/Tri-Sonics/GPS
13 cm
Tracker
7 cm