68
iCON grade, Calibrating the System
3.9
Configuration of Auto / Manual Switches
How to configure
the Auto / Manual
switches
1. Enter Tech Mode (
and
).
2. Enter
Hydraulic
and select
A/M Mode
at the very end.
3. Use the up/down arrow keys on the MENU Button to cycle through
Toggle
,
Master
,
Switch
.
•
Toggle
: Will set the Auto/Manual Switch to function like a doorbell
for use when the switch is a push-button. However, it will control
all hydraulics at once when prepared auto is enabled with the auto
buttons on the panel.
•
Switch
: Will set the Auto/Manual Switch to function like a light
switch with an on/off - up/down operation.
•
Master
: Will set the Auto/Manual Switch to function like a light
switch with an on/off - up/down operation. However it will control
all hydraulics at once (left/right/side or lift/tilt).
•
Master Toggle
: Will set the Auto/Manual Switch to function like a
light switch with an on/off - up/down operation. However it will
control all hydraulics at once (left/right/side or lift/tilt). With door-
bell behaviour.
4. Select
ESC
to exit menu.
NOTE ON CAT-INTERFACES: The Auto/Manual Switch will override the
joystick control on these machines.