42
iCON grade, Calibrating the System
2. Park the machine on a flat, hard and level surface, preferably a paved
road or similar. This will facilitate turning the machine around and
facilitate proper machine alignment. If the machine is already aligned
properly and is ready for calibration, skip ahead by pressing
Skip
. To
start, press
Next
.
3. Straighten the machine’s front wheels and articulation. This ensures
correct values for calibrating the mainfall sensor. Press
Next
when
complete.
4. Centre the machine link bar. It must be set in its centred position for
proper Cross Slope calibration. Press
Next
when complete.