Group 2
Safety
Page 21
JET2 neo
Release R1.12 en
Ventilation in the hydraulic cabinet
HV-cutoff at creepage current
Plastic containers are arranged in the
field of metal surfaces (PE-potential)
HV- and ink cutoff as well as nozzle sealing
at HV-flashovers
2.9 Safety measures at the place of installation
Mains connection!
The device has no mains switch and must only be connected to a easy
accessible plug socket in the direct vicinity of the place of setting up!
Installation of the device
The device must be installed in a well ventilated room only and must be kept
away from any source of heat, flame or sparks, e.g. radiant heater, etc.
Caution
– Danger of explosion!
The device should be only operated outside of explosive areas!
The installation has to be carried out according to the installation
instructions of the manufacturer!
The device has to be integrated in the lightning protection concept of the
operator!
Precautions regarding electrostatics have to be carried out!
A place of setting up must be selected with sufficient load bearing capacity
and stability. When setting up it must be observed that sufficient movement
space is available for the operating and service personnel. Solvents are
processed in the device, sufficient room ventilation must be ensured!
Prior to assembly the place of setting up must be cleaned of dirt and
contamination (residue of lubricants etc.). The working place surroundings
should be kept clean at all times in order to ensure unrestricted access to the
LEIBINGER JET2neo device.
Содержание JET2 neo
Страница 1: ...Manual LEIBINGER JET2NEO Release 1 12en ...
Страница 2: ......
Страница 11: ...Group 1 Table of contents Page 9 JET2 neo Release R1 12 en ...
Страница 12: ......
Страница 21: ...Group 2 Safety Page 19 JET2 neo Release R1 12 en 2 4 Safety sticker Figure 1 Safety sticker ...
Страница 276: ...Page 274 Appendix Group 12 Release R1 12 en JET2 neo Interface X4 Inputs Interface X3 Outputs ...