Page 154
Data entry/Programming
Group 7
Release R1.12 en
JET2 neo
1. Control switched on/off and actuate single components:
With the button
<Control>
(1) the control is switched on or off. If the control is
deactivated, the buttons of the individual hydraulic components are activated.
The components can now be switched on or off and the compressor and the suction
pump activated by pressing the respective button. The activated function of an
individual component only remains active for as long as the respective button is kept
pressed.
The respective status of a component (On/Off) and its values are shown in the
status
displays
(2).
2. Compressor and suction pump (change temporary set point values):
With the appropriate
arrow buttons
(6) the nominal values of the individual
components „compressor“ and „suction pump“ can be changed temporarily, whereby
the values are increased or reduced by one step.
3. Diaphragm position:
In the status display
<Diaphragm position>
(5) the momentary position of the
diaphragms is displayed.
4. Viscosity measurement:
The JET2neo automatically carries out a viscosity measured at approx. 60 second
intervals. The measured value is shown in the corresponding status display.
By pressing the button
<Visco measurement>
(7) a viscosity measurement can be
made at the current time.
Attention!
For further information please contact the Leibinger-Service
Department or your authorized dealer!
Содержание JET2 neo
Страница 1: ...Manual LEIBINGER JET2NEO Release 1 12en ...
Страница 2: ......
Страница 11: ...Group 1 Table of contents Page 9 JET2 neo Release R1 12 en ...
Страница 12: ......
Страница 21: ...Group 2 Safety Page 19 JET2 neo Release R1 12 en 2 4 Safety sticker Figure 1 Safety sticker ...
Страница 276: ...Page 274 Appendix Group 12 Release R1 12 en JET2 neo Interface X4 Inputs Interface X3 Outputs ...