Group 8
Job editor
Page 229
JET2 neo
Release R1.12 en
8.6.3.2 Functional area Counter parameter 2
In the functional area
<Counter page 2>
you can define the following settings:
Start value
Counter reset(methods)
Initial value
End value control
End value
Figure 139
Print elements (Counter menu (Functional area “Counter page 2”))
1
– Register cards
5
– Selection <Counter (Loop/Stop)>
2
– Display field <Start value>
6
– Pop-up window <Counter reset>
3
– Display field <Initial value>
7
– Button <OK (
)>
4
– Display field <End value>
8
– Button <Close>
8.6.3.2.1 Start value
The setting defines the start value of the counter. The maximum input is 10 digits.
After reaching the end value the counter will be reset to the start value.
The set value is displayed on the accordant display field.
8
3
2
6
5
4
7
1
Содержание JET2 neo
Страница 1: ...Manual LEIBINGER JET2NEO Release 1 12en ...
Страница 2: ......
Страница 11: ...Group 1 Table of contents Page 9 JET2 neo Release R1 12 en ...
Страница 12: ......
Страница 21: ...Group 2 Safety Page 19 JET2 neo Release R1 12 en 2 4 Safety sticker Figure 1 Safety sticker ...
Страница 276: ...Page 274 Appendix Group 12 Release R1 12 en JET2 neo Interface X4 Inputs Interface X3 Outputs ...