Group 7
Data entry/Programming
Page 121
JET2 neo
Release R1.12 en
Select the desired time by scrolling the hour and minute block. The setting block is
closed by clicking on the block again or on thes display window
<Interval on>
and the
time is saved.
Now carry out the settings in the display window
<Interval off>
(3) accordingly.
Now activate if necessary the viscosity control by clicking on the control box (5). An
activated control is displayed by a
in the control box.
Figure 66
Interval operation (Set interval time)
Switched off viscosity control
Switched on viscosity control
1
– Register card <Interval>
4
– Setting block
2
– Display field <Interval on>
5
– Control box <Visco control>
3
– Display field <Interval off>
7.2.3.1.4 Interfaces (Encoder interface)
Under the register card
< Interfaces>
you can set the interface for the incremental
encoder and you can also switch on or off the bounce time delay. The bounce time delay
is required for working with external jobs.
How can you explain the terms „bounce time“ and „bounce time delay“?
Bounce time:
Describes the period which a signal requires after an input has been switched to
reach a defined status (0 or 1) again.
1
3
S
cr
o
ll
2
5
4
Содержание JET2 neo
Страница 1: ...Manual LEIBINGER JET2NEO Release 1 12en ...
Страница 2: ......
Страница 11: ...Group 1 Table of contents Page 9 JET2 neo Release R1 12 en ...
Страница 12: ......
Страница 21: ...Group 2 Safety Page 19 JET2 neo Release R1 12 en 2 4 Safety sticker Figure 1 Safety sticker ...
Страница 276: ...Page 274 Appendix Group 12 Release R1 12 en JET2 neo Interface X4 Inputs Interface X3 Outputs ...