Page 46
Transport/Start up
Group 5
Release R1.12 en
JET2 neo
Basic data/Recommended working conditions:
Signal
Parameter
Value
PrintGo
For
PNP
-sensors
Input level High
15 up to 30V
Input level Low
-3,5V up to 3,5V (or high resistance)
Minimum pulse duration
100µS
Input resistance
6,8 kOhm
PrintGo
For
NPN
-sensors
Input level High
20 up to 28V (or high resistance)
Input level Low
-6V up to 9V
Minimum pulse duration
100µS
Input resistance
6,8kOhm
PrintGo Gate
For
PNP
-sensors
Input level High
15 up to 30V
Input level Low
-3,5V up to 3,5V (or high resistance)
Minimum pulse duration
100µS
Input resistance
6,8 kOhm
You will find a circuit diagram of the interface in the appendix of this
manual!
(1)
All 24V outputs designated with (1) are protected by a self-reset fuse with 700 mA.