Group 9
Equipping/maintenance
Page 149
Release 3.00
Leibinger-Jet 2 se
Checking of the jet cleaning carried out
With repeated switching of the ink flow valve (by pressing of the ink on/off switch) the ink
jet must always assume the same position. If this is not the case, renewed cleaning is
necessary.
9.4.3.2 Cleaning the suction pump
The content is under pressure even if the device has been
disconnected from the mains supply!
Ink under pressure can spray out. Prior to opening disconnect the
device from the mains supply and let off the pressure!
Risk of injury!
Spraying of ink into the eyes can cause blindness. Prior to the
opening of the device eye protection must be put on!
Risk of injury!
Upon contact the contents causes skin irritation. Protective
equipment is necessary!
This work must only be carried out by trained personnel or by
Leibinger service technicians!
Figure 113
Suction pump
(54-002 002 S)
The suction pump works with an
underpressure > 0.3 bar. If this is not
achieved, dirtying of the valve reeds or
damage to the working membrane can
be present.
Содержание Jet 2
Страница 21: ...Group 2 Safety instructions Page 21 Release 3 00 Leibinger Jet 2 se 2 5 Safety sticker Figure 1 ...
Страница 54: ...Group 6 Operation procedures and elements Page 54 Release 3 00 Leibinger Jet 2 se 6 3 5 Menu structure ...
Страница 55: ...Group 6 Operation procedures and elements Page 55 Release 3 00 Leibinger Jet 2 se ...
Страница 56: ...Group 6 Operation procedures and elements Page 56 Release 3 00 Leibinger Jet 2 se ...
Страница 160: ...Group 12 Appendix Page 160 Release 3 00 Leibinger Jet 2 se Figure 117 Interface layout plan part no 2 ...
Страница 167: ...Group 12 Appendix Page 167 Release 3 00 Leibinger Jet 2 se 12 6 Technical drawings Figure 119 Print head SK2 ...
Страница 168: ...Group 12 Appendix Page 168 Release 3 00 Leibinger Jet 2 se Figure 120 Cabinet LJ 2 ...