Group 6
Operation – description of the device
Page 67
Release 3.00
Leibinger-Jet 2 se
6.5.4.4 Leak detection
An additional safety measure in the LEIBINGER-JET 2 is the leak detection. To detect a
leak in the hydraulic part i.e. if ink or solvent on the basis of slightly combustible solvents
escape, the operation of the device is aborted and an acoustic alarm triggered.
Figure 35
Leak
detection
1 – Leak sensor (54-003 340 SA)
6.5.5 Print head
Dangerous electrical voltage!
Contact causes serious damage through an electric shock!
Disconnect the device from the mains supply prior to opening.
Remove mains plug!
The content is under pressure even if the device has been
disconnected from the mains supply!
Ink under pressure can spray out. Prior to opening disconnect the
device from the mains supply and let off the pressure!