6.5.3 DC power supply
Dangerous electrical voltage!
Contact causes serious damage through an electric shock!
Disconnect the device from the mains supply prior to opening.
Remove mains plug!
The direct currents of the LEIBINGER-JET 2 are achieved through a power supply with
automatic input voltage recognition. It has "Power Factor Compensation" and is
permanently short circuit resistant or switches off independently in the event of overload.
It is protected by a safety fuse. The output voltages cannot be altered.
The mains part provides the following output voltages:
V1:
+ 5,0 Volt
V2:
+ 5,0 Volt
(standby supply voltage)
V3:
+ 18,0 Volt
V4:
- 18,0 Volt
V5:
+ 24,0 Volt
V6:
+ 2- 8 KV
Figure 28
1 – Main fuses (2x)
F1,6 H
(54-003 339 KA)
Ink jet power supply
(54-001 949 SB)
For service purposes the power supply and the fuses are accessible from the front side
of the device.
This work must only be carried out by trained personnel or by
Leibinger service technicians!
It is imperative that you observe the instructions on the subject of fuse
changing in the group
Equipping/maintenance
in the chapter
Other
service work!
1
Содержание Jet 2
Страница 21: ...Group 2 Safety instructions Page 21 Release 3 00 Leibinger Jet 2 se 2 5 Safety sticker Figure 1 ...
Страница 54: ...Group 6 Operation procedures and elements Page 54 Release 3 00 Leibinger Jet 2 se 6 3 5 Menu structure ...
Страница 55: ...Group 6 Operation procedures and elements Page 55 Release 3 00 Leibinger Jet 2 se ...
Страница 56: ...Group 6 Operation procedures and elements Page 56 Release 3 00 Leibinger Jet 2 se ...
Страница 160: ...Group 12 Appendix Page 160 Release 3 00 Leibinger Jet 2 se Figure 117 Interface layout plan part no 2 ...
Страница 167: ...Group 12 Appendix Page 167 Release 3 00 Leibinger Jet 2 se 12 6 Technical drawings Figure 119 Print head SK2 ...
Страница 168: ...Group 12 Appendix Page 168 Release 3 00 Leibinger Jet 2 se Figure 120 Cabinet LJ 2 ...