Group 9
Equipping/maintenance
Page 137
Release 3.00
Leibinger-Jet 2 se
!
The LEIBINGER- JET 2 is without pressure and
must
be disconnected from the
mains supply.
Remove mains plug!
Figure 106
!
Undo the 2 Allan screws and remove the entire pressure tank if the tube connections
allow this (picture sequence 1).
!
Place the collection tub underneath the tank and remove both connections for the
viscosity regulation. The ink will run out. If necessary all hydraulic connections can
be removed.
!
Unscrew the 8
continuous
Allan screws that hold the pressure tank together (picture
sequence 2) and remove the lower half of the housing downwards.
The membrane
flange must not be loosened!
!
Pull off the filter and slide on the new filter (picture sequence 3).
!
Clean any possible dirt in the filter housing with thinner. Examine the O-ring for
damage and clean. If necessary replace.
Unscrew only the continuous allan screws!
4
5
1
2
3
Содержание Jet 2
Страница 21: ...Group 2 Safety instructions Page 21 Release 3 00 Leibinger Jet 2 se 2 5 Safety sticker Figure 1 ...
Страница 54: ...Group 6 Operation procedures and elements Page 54 Release 3 00 Leibinger Jet 2 se 6 3 5 Menu structure ...
Страница 55: ...Group 6 Operation procedures and elements Page 55 Release 3 00 Leibinger Jet 2 se ...
Страница 56: ...Group 6 Operation procedures and elements Page 56 Release 3 00 Leibinger Jet 2 se ...
Страница 160: ...Group 12 Appendix Page 160 Release 3 00 Leibinger Jet 2 se Figure 117 Interface layout plan part no 2 ...
Страница 167: ...Group 12 Appendix Page 167 Release 3 00 Leibinger Jet 2 se 12 6 Technical drawings Figure 119 Print head SK2 ...
Страница 168: ...Group 12 Appendix Page 168 Release 3 00 Leibinger Jet 2 se Figure 120 Cabinet LJ 2 ...