Group 7
Data Entry
Page 108
Release 3.00
Leibinger-Jet 2 se
7.6.4 Counter settings
Figure 83
With the two touch fields
<counter 1 set-
up>
(134) and
<counter 2 set-up>
(135)
the basic settings of the respective
counters are defined.
The setting level
<E42>
is activated.
Figure 84
The touch field
<start value>
(136)
enables the entry of the starting value.
Following reaching of the limit value the
counter is reset to the starting value.
With the touch field
<end value>
(137) the limit value can be defined. The starting value
can be increased to any limit value desired.
The touch field
<increment>
(138) defines the increase between the individual print
issues. The increase of the counter can be selected between 1-9.
The touch field
<repeat count>
(139) determines the number of prints to be repeated. If
no repetition is desired
“0”
must be entered. The counter can print up to 9999
repetitions.
At the same time the values are displayed in addition in the above mentioned
fields
.
The touch field
<forward/backward>
(140) controls the direction of the counting process
i.e. whether the counter is incremented (+) or decremented (-).
The touch field
<reset>
(141) controls the form of the reset. At the same time the
activated status
„normal“
or
„Prod. C.“
is displayed in the field. If the function
„Prod.
C.“
(with product counter) is activated the counter will be reset when the product counter
is reset.
137
[E42]
136
141
138
140
139
[E6]
134
135
Содержание Jet 2
Страница 21: ...Group 2 Safety instructions Page 21 Release 3 00 Leibinger Jet 2 se 2 5 Safety sticker Figure 1 ...
Страница 54: ...Group 6 Operation procedures and elements Page 54 Release 3 00 Leibinger Jet 2 se 6 3 5 Menu structure ...
Страница 55: ...Group 6 Operation procedures and elements Page 55 Release 3 00 Leibinger Jet 2 se ...
Страница 56: ...Group 6 Operation procedures and elements Page 56 Release 3 00 Leibinger Jet 2 se ...
Страница 160: ...Group 12 Appendix Page 160 Release 3 00 Leibinger Jet 2 se Figure 117 Interface layout plan part no 2 ...
Страница 167: ...Group 12 Appendix Page 167 Release 3 00 Leibinger Jet 2 se 12 6 Technical drawings Figure 119 Print head SK2 ...
Страница 168: ...Group 12 Appendix Page 168 Release 3 00 Leibinger Jet 2 se Figure 120 Cabinet LJ 2 ...