5.6 Brushes
After each product change, check the two brushes on the shaft and the cellular rotors for contamination and wear.
Clean or renew the brushes if necessary.
Removing and installing brushes
1
2
1. Remove the cellular rotor shaft,
.
2. Undo 2 screws and a cap nut
(1)
and remove the
holder
(2)
.
see "Install/Remove drive unit"
.
4. Push the brushes
(3 = crinkled fibres, 4 = smooth
fibres)
from the drive side to the blower side slight-
ly by pressing them with a flat tool (for example an
Allen key).
5. Pull the brushes
(3 = crinkled fibres, 4 = smooth
fibres)
straight out of the blower side.
6. Check the brushes and clean or renew them if nec-
essary.
7. Push the brushes back in, at least until they are
flush.
Caution:
Different brushes, make sure the arrange-
ment is correct!
8. Secure the holder with the 3 screws
(1)
.
9. Install the drive and cellular rotor shaft.