Operation
40 / 74
1.0
Vento
®
II
4.9 Error message
Message on the display
Error No.
Explanation
Cellular rotor blocked
1
•
Check cellular rotor shaft for foreign bodies and remove
blockage
Cellular rotor not responding
2
•
The control cable for the spreader is not connected to the
control panel
•
Check the control cable for damage
•
Check the connection cable for the cellular rotor drive unit
•
Check the plug on the control cable for damage
Blower blocked
3
•
Check the blower for blockages
Excess voltage
4
•
Max. voltage supply 15.5 V
Inadequate voltage
5
•
Check voltage supply (min. 12.5 V)
•
Have you used our original 6 mm² battery cable?
Travel speed too high
7
•
Maximum cellular rotor speed reached
•
Reduced travel speed or use a larger cellular rotor
Hopper empty
8
•
Residual quantity (approx. 2 l) in the hopper
Speed signal missing
9
•
No speed signal detected
•
Faulty contact or cable break on speed sensors
Overheating
10
•
Allow the control unit to cool
•
Check the ventilation openings on the side covers to ensure
they are clear
•
Keep the control unit out of direct sunlight
•
Check the power supply, is sufficient voltage being supplied
(min. 12.5 V)
Содержание Vento II