Operation
Vento
®
II
1.0
25 / 74
Product name
ABCDEFGHIJKLMNOPQRSTUV
WXYZ0123456789 .,;:-+/
Test
X«
«–
aA
OK
8. Select "OK" and confirm to save the product name.
Calibration test
Automatic
40
rpm
80
rpm
9. Select the speed of the rotary feeder shaft.
Advice
Depending on the speed and granu-
late, the cellular rotors might not be
filled completely. This can result in
variances in the output quantity.
Recommendation:
Fine granulate: 80 rpm
Coarse granulate: 40 rpm
Calibration test
Automatic
30
s
60
s
90
s
10. Select the duration of the calibration test.
Advice
The accuracy of the calibration test in-
creases with its duration and the grain
size of the material.
Fine material: less time
Coarse material: more time
11. Turn the turn-and-push button to select the duration
of the calibration test.
12. Save the entry by pressing the turn-and-push but-
ton.
The entry will be confirmed.
Calibration test
60
s
[Start]
The start menu for the calibration test appears.
Advice
By turning the turn-and-push button
quickly to the left or right, you can skip
the countdown and the weight can be
entered or edited in the program.