4.10 Troubleshooting
No signal from the wheel sen-
sor
•
Check the distance between the sensor and wheel nuts and adjust if nec-
essary. Distance should be less than or equal to 4 mm.
•
Check the wheel sensor/control panel plug connection.
•
Check the counting points.
•
Check the cables.
No signal from the linkage mag-
netic sensor
•
Distance between the sensor and magnet too large.
•
Note the installation direction of the sensor,
see "Install the electronic link-
.
•
Check the cables.
Output rate excessive/insuffi-
cient
•
Perform a calibration test, enter the correct value and confirm.
•
Check the quantity adaptation.
•
Check the cellular rotor for contamination.
•
Check the brushes for signs of damage and contamination,